Virtual planning
Put together your individual van racking system.
Leakage current: 5 µA ... 10 mA DC / AC, 50Hz ... 1MHz
This state-of-the-art leakage current meter offers a first-class solution for ensuring the protection and safety of electrical products. Insulation faults can cause leakage currents that can potentially endanger the operator or user of an electrical device.
Developed to meet the specific requirements of industry, it enables efficient measurement under a wide range of operating modes.
An external input is available to supply the test objects with a wide range of voltages. Thanks to its robust design and simple operation, it is the ideal choice for demanding environments.
Leakage current measurements are only possible in conjunction with the elution two software.
5 µA ... 10 mA DC / AC, 50Hz ... 1MHz
3 leakage current measuring ranges: 0.1mA / 1mA / 10mA
Measurement types: I_trms, I_ac, I_dc, I_peak, I_mad (depending on the test standard used)
Fixed measuring range according to I_lc_max or automatic measuring range adjustment
External supply
50 ... 280 V AC 1-phase, max. 15A, 50 ... 400 Hz
90 ... 490 V AC 3-phase, max. 32A, 50 ... 400 Hz
Monitoring the supply voltage of the device under test with min. values
Monitoring the current consumption of the test object with min. values
(for 3-phase DUTs, phase L1 is monitored)
Optional with supply unit
1s ... 1d adjustable in 0.1s steps
Variable test sequence
Operating modes A1...A8
External supply (DUT)
DUT connection, 1-phase, vi1, vi2
Additional connections for tests in accordance with EN60601-1, MED
Ethernet interface (RJ45 socket)
Warning lamp set connection
Remote control connection Remove Control with display
Digital input / output connection
230 V +/- 10 %; 49 .. 61 Hz
Integration in control cabinets via 6-point rack mounting
Width: 426mm
Height: 392mm
Depth: 235mm
16 kg
Elution® Device
N2-4D
Basic measuring circuits for integration into the Smart - Modular leakage current measuring modules
Basic measuring circuit according to EN60990 Fig. 3 / 4 / 5
The basic measuring circuit contains the three measuring circuits described in the basic standard EN60990 under Fig. 3, 4 and 5 and enables standard-compliant leakage current testing. The connection is made according to the respective product standard.
SM-LCXP-X-E100
Basic measuring circuit in accordance with EN60601 Figure 12
The basic measuring circuit contains the three measuring circuits described in the EN60601 standard in Figure 12 and enables standard-compliant leakage current testing. The connection is made in accordance with the product standard.
SM-LCXP-X-E101
Basic measuring circuit according to EN61029 UL / CSA
SM-LCXP-X-E102
Test standard EN60335-1, 1-phase / status 08-2020
SM-EN60335-20-1
Test standard EN60335-1, 1/3-phase / Version 02-2020
SM-EN60335-20-1
Test standard EN60598-1, 1-phase / Version 03-2022
SM-EN60598-22-1
Test standard EN60601-1, 1-phase / Version 12-2013
SM-EN60601-13-1
Test standard EN60601-1, 1/3-phase / Version 12-2013
SM-EN60601-13-3
Test standard EN60601-1, 1-phase with medical supplement
SM-EN60601-13-1M
Test standard EN60601-1, 1/3-phase with medical add-on
SM-EN60601-13-3M
Test standard EN60730-1, 1-phase / status 10-2009
SM-EN60730-09-1
Test standard EN61010-1, 1-phase / Version 03-2020
SM-EN61010-20-1
Test standard EN61010-1, 1/3-phase / Version 03-2020
SM-EN61010-20-3
Test standard EN61588-1, 1-phase / status 08-2010
SM-EN61588-10-1
Test standard EN61588-1, 1/3-phase / Version 08-2010
SM-EN61588-10-3
Test standard EN62368-1, 1-phase / Version 05-2021
SM-EN62368-21-1
Test standard EN62368-1, 1/3-phase / Version 05-2021
SM-EN62368-21-3
Test standard EN62481-1, 1-phase / Version 04-2014
SM-EN62481-14-1
Test standard EN62481-1, 1/3-phase / Version 04-2014
SM-EN62481-14-3
Further test standards on request
Remote control with 6m connection cable
SM-ACC-10
Warning light red / green
SM-ACC30