Leakage current test system for single-phase DUTs

Maximise safety and efficiency

Leakage current test system for single-phase DUTs

Maximise safety and efficiency

Leakage currents can arise from insulation faults, potentially posing a hazard to operators or users of electrical equipment.

This state-of-the-art leakage current measuring device provides a premium solution to ensure the protection and safety of electrical products.

Designed to meet the specific requirements of the industry, it enables efficient measurement across a variety of operating conditions.

An external input is available to supply the device under test with a range of different voltages.

Thanks to its robust construction and user-friendly operation, it is the ideal choice for demanding environments.

Leakage current measurements are only possible in conjunction with the Elution software.

Ableitstrommessgerät SM-LC1P-0-ZRM

  • Comprehensive leakage current test with detailed connection for 1-phase DUTs
  • Automated logging and good/fault statistics
  • Flexible 6-point rack mounting

Leakage current measurements

Measuring bandwidth: 5 µA ... 10 mA DC / AC, 50Hz ... 1MHz

3 leakage current measuring ranges: 0.1mA / 1mA / 10mA

Measurement types: I_trms, I_ac, I_dc, I_peak, I_mad (depending on the test standard used)

Fixed measuring range according to I_lc_max or automatic measuring range adjustment

Supply of the test object

External supply

50V ... 280V AC, 1-phase, max. 15A (rev. fused), 50 ... 400Hz

Monitoring of the supply voltage of the device under test with min./max. values

Monitoring the current consumption of the device under test with min. values

Optional with supply unit

Test time / warm-up time

1s ... 1d adjustable in 0.1s steps

Test sequences

Variable test sequence

Operating modes

  • Normal operation without error
  • Normal mode with N fault
  • Normal operation with PE fault
  • Reverse polarity operation without fault
  • Reverse polarity operation with N-fault
  • Reverse polarity operation with PE fault

DUT connections

DUT connection, 1-phase, vi1, vi2

Additional connections for tests in accordance with EN60601-1, MED

External supply (DUT)

Interfaces

Ethernet interface (RJ45 socket)

Warning lamp set connection

Remote control connection Remove Control with display

Digital input / output connection

Mains voltage

230 V +/- 10 %; 49 .. 61 Hz

Size

Integration in control cabinets via 6-point rack mounting

Width: 426mm

Height: 220mm

Depth: 235mm

weight

8.5 kg

Software package

Elution Device
N2-4D

Basic measuringcircuits
- Elabo Basic measuring circuits for integration into the Elabo Smart - Modular leakage current measuring modules

- Basic measuring circuit according to EN60990 Fig. 3 / 4 / 5
The basic measuring circuit contains the three measuring circuits described in the basic standard EN60990 under Fig. 3, 4 and 5 and enables standard-compliant leakage current testing. The connection is made according to the respective product standard.
SM-LCXP-X-E100

- Basic measuring circuit in accordance with EN60601 Figure 12.
The basic measuring circuit contains the three measuring circuits described in the EN60601 standard in Figure 12 and enables standard-compliant leakage current testing. The connection is made in accordance with the product standard.
SM-LCXP-X-E101

- Basic measuring circuit according to EN61029 UL / CSA
SM-LCXP-X-E102

Test standards

Test standard EN60335-1, 1-phase / status 08-2020
SM-EN60335-20-1

Test standard EN60335-1, 1/3-phase / Version 02-2020
SM-EN60335-20-1

Test standard EN60598-1, 1-phase / Version 03-2022
SM-EN60598-22-1

Test standard EN60601-1, 1-phase / Version 12-2013
SM-EN60601-13-1

Test standard EN60601-1, 1/3-phase / Version 12-2013
SM-EN60601-13-3

Test standard EN60601-1, 1-phase with medical supplement
SM-EN60601-13-1M

Test standard EN60601-1, 1/3-phase with medical add-on
SM-EN60601-13-3M

Test standard EN60730-1, 1-phase / status 10-2009
SM-EN60730-09-1

Test standard EN61010-1, 1-phase / Version 03-2020
SM-EN61010-20-1

Test standard EN61010-1, 1/3-phase / Version 03-2020
SM-EN61010-20-3

Test standard EN61588-1, 1-phase / status 08-2010
SM-EN61588-10-1

Test standard EN61588-1, 1/3-phase / Version 08-2010
SM-EN61588-10-3

Test standard EN62368-1, 1-phase / Version 05-2021
SM-EN62368-21-1

Test standard EN62368-1, 1/3-phase / Version 05-2021
SM-EN62368-21-3

Test standard EN62481-1, 1-phase / Version 04-2014
SM-EN62481-14-1

Test standard EN62481-1, 1/3-phase / Version 04-2014
SM-EN62481-14-3

Accessories

Remote control with 6m connection cable with
SM-ACC-10

Warning light red / green
SM-ACC30

Measuring and testing devices

Are you interested in measuring and testing devices from bott? Get in touch with us!